Tronsoft Technologies

Hazardous Area Classification

Posted by Admin on February, 05, 2022

Hazardous areas are classified into zones based on an assessment of the frequency of the occurrence and duration of an explosive gas atmosphere, as follows:

  • Zone 0: An area in which an explosive gas atmosphere is present continuously or for long periods;
  • Zone 1: An area in which an explosive gas atmosphere is likely to occur in normal operation;
  • Zone 2: An area in which an explosive gas atmosphere is not likely to occur in normal operation and, if it occurs, will only exist for a short time.

Various sources have tried to place time limits on to these zones, but none have been officially adopted. The most common values used are:

  • Zone 0: Explosive atmosphere for more than 1000h/yr
  • Zone 1: Explosive atmosphere for more than 10, but less than 1000 h/yr
  • Zone 2: Explosive atmosphere for less than 10h/yr, but still sufficiently likely as to require controls over ignition sources.



Tronsoft is a supplier of MTL zener barriers and signal isolators (MTL5500 series, MTL7700 series) etc. Along with many other products like surge protection devices, Electromagnetic flow meters from reputed brands like Krohne Marshall, Eureka , EnH etc

Check our Intrinsically safe productline here: https://www.tronsoft.co.in/intrinsic-safety.htm



This entry was posted on February, 05, 2022 at 19 : 44 pm and is filed under Hazardous area classification. You can follow any responses to this entry through the RSS 2.0 feed. You can leave a response from your own site.

Leave a Comment

(required)
(required) (will not be published)


Looking for Product Name ?

Raise your Query

Hi! Simply click below and type your query.

Our experts will reply you very soon.

WhatsApp Us